colorCONTROL C4
49
Example 31: DATA FRAME with ORDER NUMBER = 31:
ORDER NUMBER (second word = 31): Write calibration factors Offset RED, Offset GREEN, Offset BLUE from PC
into EEPROM!
The completely data frame = 18 words must be sent to the sensor hardware in binary form
(sync-word / order-word / 16 parameter words).
DATA FRAME PC Æ Sensor (18 WORDS)
0x0055 SYNC.-WORD
31 ORDER-WORD
VALUE OFFSET RED
VALUE OFFSET GREEN
VALUE OFFSET BLUE
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
DATA FRAME Sensor Æ PC (18 WORDS)
0x00AA SYNC.-WORD
31 ORDER-WORD
VALUE CF RED
VALUE CF GREEN
VALUE CF BLUE
VALUE OFFSET RED
VALUE OFFSET GREEN
VALUE OFFSET BLUE
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
Vista de página 49