Example 1: DATA FRAME with ORDER NUMBER = 1:
ORDER NUMBER (second word = 1): WRITE parameters from PC into RAM of the sensor!
The completely data frame = 18 words must be sent to the sensor hardware in binary form
(sync-word / order-word / 16 parameter words).
DATA FRAME PC Æ Sensor (18 WORDS) DATA FRAME Sensor Æ PC (18 WORDS)
0x00AA SYNC.-WORD
0x0055 SYNC.-WORD
1 ORDER-WORD
200 POWER
0 POWER MODE
1024 AVERAGE
0 EVALUATION MODE
10 HOLD
10 INTLIM
5 MAXCOL-No.
0 OUTMODE
0 TRIGGER
0 EXTEACH
0 CALCULATION MODE
3000 DYN WIN LO
3500 DYN WIN HI
0 COLOR GROUPS
1 INTEGRAL
0 DUMMY
1 ORDER-WORD
200 POWER
0 POWER MODE
1024 AVERAGE
0 EVALUATION MODE
10 HOLD
10 INTLIM
5 MAXCOL-No.
0 OUTMODE
0 TRIGGER
0 EXTEACH
0 CALCULATION MODE
3000 DYN WIN LO
3500 DYN WIN HI
0 COLOR GROUPS
1 INTEGRAL
0 DUMMY
Example 3: DATA FRAME with ORDER NUMBER = 3:
ORDER NUMBER (second word = 3): READ parameters out of sensor-RAM memory!
The same frame as example 1 must be sent to the sensor except of the order word that must be 3. The values for
the parameters must be sent as Dummies.
The complete DATA FRAME which is responded by the sensor is 18 words.
DATA FRAME PC Æ Sensor (18 WORDS)
DATA FRAME Sensor Æ PC (18 WORDS)
0x00AA SYNC-WORD
3 ORDER-WORD
200 POWER
0 POWER MODE
1024 AVERAGE
0 EVALUATION MODE
10 HOLD
10 INTLIM
5 MAXCOL-No.
0 OUTMODE
0 TRIGGER
0 EXTEACH
0 CALCULATION MODE
3000 DYN WIN LO
3500 DYN WIN HI
0 COLOR GROUPS
1 INTEGRAL
0 DUMMY