The text below describes a teach process with EVALUATION MODE = BEST HIT and CALCULATION MODE =
X/Y/INT.
Step 1:
Prior to the use of the software aids (graphic display of sensor signals) the sensor must be manually adjusted to
the respective target or background as accurately as possible. The reference distance of the sensor to the target is
defined in the data sheet of the respective sensor.
Please make sure that the sensor is properly connected and supplied with power. Furthermore the sensor head
must be directed onto the brightest surface (paper, leather, glass, etc.) of the color to be taught. This is absolutely
necessary for being able to set a suitable POWER value for the sensor.
Step 2:
Start the colorCONTROL C4 V6.4 software. Please check whether the status line at the right bottom displays the
„colorCONTROL C4 V6.4 RT:KWxx/xx “ message.
Info: Moving the mouse cursor to a control element and clicking with the right mouse button displays a short info
on the respective individual control element.
colorCONTROL C4
33